  ① pump should be installed horizontally, not upright, vertical mounting for the special requirements of the occasion, the motor must be upward.

  ② start before the suction pipe valve can be opened, if suction liquid level below the shaft center line, pipeline to be equipped with a foot valve.

  ③ pumps should be carried out before checking motor fan rotation should be flexible, not stuck no abnormal sound, each fastener to be tightened.

  ④ Check the motor rotation direction is consistent with markers and magnetic steering pump.