Cause fever melt pump extrusion machine running
machine causes fever melt pump extrusion runs as follows:
① cause the rotation of the reasons for poor melt pump extrusion melt pump extrusion can cause fever.
② oil viscosity is too high or too low. Workaround - Re-election of oil.
③ side panels, sleeve and the gear face serious friction. Workaround - repair or replacement.
④ ambient temperature is high, small fuel tank capacity, poor heat dissipation, heat will cause the pump. Workaround - should be treated separately.
melt pump extrusion run the following reasons for poor rotation as follows:
1. concentricity poor coupling with the engine. Workaround - should ensure concentricity within 0.1mm.
2. The internal parts are not demagnetization. Workaround - all parts before assembly shall demagnetization.
3. The needle sets unqualified or needle breakage. Workaround - repair or replacement.
4.melt pump extrusion working oil output port is blocked. Workaround - remove foreign bodies.
5. The pump shaft is too small or radial gap to gap. Workaround - Re-adjusted repair.
6.melt pump extrusion in the dirt. Workaround - disintegration to remove foreign matter.
7. The assembly is incorrect. Workaround --melt pump extrusion two pin hole machining plane was not fitted plane, such as a pin into the first, and then tighten the screw, the pump will not turn. Workaround - side rotary gear pump side and tighten the screws, and finally with a diamond pin hole and into the pin.